Study of the role of the earth & a differential circuit-breaker

This very visual didactic model will make students aware of the risks and dangers of electrocution and teach them the role of earth and a differential circuit breaker.
Educational objectives
• Educating students about the risks of electrocution in the event of direct contact
• Educating students about the risks concerning the quality of the earth
• Showing the role of a 30mA residual current circuit breaker in a house

Selected reference SELDIF
Quantity

Selected reference SELDIF
Selected reference SELDIF

Practical work supplied
No earth and no insulation fault
• potential risk

Earth < 100Ω and net insulation fault
• with person in contact with the metal enclosure of the machine
• with no contact
Appearance of a fault current greater than 30mA, tripping of the differential.
Demonstration of the short circuit.

Earth < 100Ω and low insulation fault
Appearance of a fault current less than 30mA, no tripping of the differential.
Measurement of the fault current in the person in contact with the machine.

Earth > 100Ω and low insulation fault
Appearance of a fault current less than 30mA, no tripping of the differential.
Measurement of the fault current in the person in contact with the machine

Earth > 100Ω and net insulation fault
• with person not in contact with the metal enclosure of the machine measurement of the fault current
• with person in contact with the enclosure: measurement of the fault current greater than 30mA, no tripping of the differential. LED symbolizing the heart, coming on.

The front synoptic shows
• the public network, with its medium voltage/low voltage transformer substation, and the neutral to earth connection, in this substation.
• the transmission line from the transformer substation to the dwelling
• the domestic installation, with the residual current circuit-breaker 30mA, the local earth, and a washing machine. The TT neutral system is the same as that of a domestic installation
• A person in the right-hand part has an LED for a heart. If a dangerous leakage current flows here, the LED comes on
• A two-pole industrial residual current circuit-breaker 30mA is located in the centre of the synoptic.
• Two jumpers enable the washing machine to be fully isolated, and current measurements to be taken.
• An ON pushbutton starts the washing machine, and a green LED comes on, symbolizing rotation of the machine.

Safety terminals 4mm, located on the front, let the student measure the fault currents, and insert
different resistive modules. These modules simulate two earth resistance values, and two leakage
current values. One module with variable resistance enables the differential's tripping current to be measured.

To prevent any risk of electrocution to the student, the model operates at extra low voltage using an isolating transformer to standard NFC61558.

 

 

You may also be interested in these products

  • icon-devis

    Free
    quotation

  • icon-temps

    Answer
    under 48H00

  • icon-livraison

    Delivery
    worldwide

  • icon-medal

    2 years warranty
    for all our products

  • icon-service

    Export service
    available

Do you need help ?

You can't find a product,

You want technical informations,

You want to talk with us

Contact us
Find out all the useful contacts
Where to find us ?